Demirtas, Huseyin2024-09-292024-09-2920220267-08361743-2847https://doi.org/10.1080/02670836.2022.2081447https://hdl.handle.net/20.500.14619/5640The present study investigated the mechanical performance of Ti-8Nb-8Zr-8Cu (at.-%) alloys containing different porosity levels. Metallographic examination and phase analysis of samples was performed by scanning electron microscope (SEM), optical microscopy (OM), energy dispersive spectrometry (EDS) and X-ray diffraction (XRD) measurements. The mechanical properties were detected by uniaxial compression test, micro and macro hardness measurements. The wear behaviour was determined by a dry wear test on the bulk sample. The ultimate compressive strength decreased from 1077.30 to 344.65 MPa with 50% porosity and the modulus of elasticity from 15.6 to 9.5 GPa. These values show that it may be suitable for bone replacement considering the stress shield effect.eninfo:eu-repo/semantics/closedAccessPorosityTi alloypowder metallurgyammonium carbonatebiomaterialsThe effect of porosity on the mechanical properties of Ti-8Nb-8Zr-8Cu alloyArticle10.1080/02670836.2022.20814472-s2.0-85131689809112614Q2111838WOS:000807595200001Q3