Erkaymaz, H.Orak, I.M.Özer, M.2024-09-292024-09-292014978-147994874-1https://doi.org/10.1109/SIU.2014.6830216https://hdl.handle.net/20.500.14619/92822014 22nd Signal Processing and Communications Applications Conference, SIU 2014 -- 23 April 2014 through 25 April 2014 -- Trabzon -- 106053Coding of the organ movements have been seen commonly in the hardware designing which is useful for humanity in scientific researches. 5 sense organs which reveal different data with cellular structures, is the most important focus point. Especially, Eye is known as photosensitive sensor organ of living creature. There is a potential difference between cornea and retina of eye. This potential difference is known as electrooculogram (EOG). Nowadays, EOG signals are commonly used in these hardware designs. Obtained potential differences from EOG signals have been converted coded directional movements. Thus, in this study, 4 basic direction movements have been tried to detect with a fuzzy controlled model. It is shown that the fuzzy controlled system as determine the direction can be used successfully. In addition, eye direction movements of squint person are obtained by the system. © 2014 IEEE.trinfo:eu-repo/semantics/closedAccessDiplopiaDirection DetectEOGFuzzy ControlerElectrooculogram and diplopia controlled fuzzy direction detect systemElektrookülogram ve göz kaymasi kontrollü bulanik yön tespit sistemiConference Object10.1109/SIU.2014.68302162-s2.0-84903766026268N/A265