Yazar "Afzal, Asif" seçeneğine göre listele
Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Energetic, exergetic, and thermoeconomic analyses of different nanoparticles-added lubricants in a heat pump water heater(Elsevier, 2022) Yildiz, Gokhan; Agbulut, Umit; Gurel, Ali Etem; Ergun, Alper; Afzal, Asif; Saleel, C. AhamedThe heat pumps are frequently used in domestic and industrial applications for hot water supply. The present paper aims to thermodynamically investigate the impacts of the nanoparticle-addition into the lubricants on the energetic, exergetic, and thermoeconomic aspects of a heat pump. In the experiments, air to the water heat pump is separately charged with various metal oxide-based nanoparticles (Al2O3, CuO, and TiO2)-added oils at a constant mass fraction of 0.5%. Polyolester (POE) and 134a are used as a lubricant, and refrigerant, respectively. The mass flow rates of the water passed through the condenser are varied from 10 to 25 g/s with an interval of 5 g/s. In the results, it is observed that the thermal conductivity value noteworthy increases with the presence of nanoparticles in POE. The highest increment in thermal conductivity is found to be 39% for POE + CuO in comparison with that of pure POE. Furthermore, with nanoparticles addition, it is noticed that the COP value generally improves, and the highest improvement for COP value is noticed to be 8% for POE + TiO2 nanolubricant at the mass flow of 25 g/s. Furthermore, exergy efficiency enhances by 3.6%, 1.8%, and 4.5% for POE + Al2O3, POE + CuO, and POE + TiO2, respectively. The lowest heating cost is calculated to be 3.465 c/kWh at 20 g/s flow rate for POE + Al2O3. In conclusion, this paper clearly reports that usage of nanoparticles along with lubricants is presenting better energetic, exergetic, and thermoeconomic results rather than the usage of lubricant alone in the heat pumps.Öğe Exergy, sustainability and performance analysis of ground source direct evaporative cooling system(Elsevier, 2022) Yildiz, Gokhan; Ergun, Alper; Gurel, Ali Etem; Ceylan, Ilhan; Agbulut, Umit; Eser, Servet; Afzal, AsifA significant portion of global energy consumption is due to energy consumption in the buildings. Heating, cooling, and air conditioning systems have the largest share in this energy consumption. Evaporative cooling systems, which have the advantage of being economical, zero pollution, and easy maintenance are preferred to reduce energy consumption in buildings. These systems are used in many areas such as greenhouses, broiler houses, and warehouses. In this study, analyzes of exergy, sustainability, and cooling efficiency in four different situations of a ground source direct evaporative cooling system were made. The system was studied in four different cases. While the highest exergy efficiency was obtained in case 3 with 20.83%, the exergy efficiencies in other cases were obtained as 16.83%, 17.49%, and 18.36%, respectively. In addition, the highest specific exergy loss was determined as 100.51 J/kg in case 2, while it was calculated as 73.08 J/ kg, 80.23 J/kg, and 73.05 J/kg for the other cases, respectively. It is seen that the sustainability values are in parallel with the exergy efficiency when the evaporative cooling system is examined for four different cases. The sustainability values were determined as 1.20 for case 1, 1.21 for case 2, 1.26 for case 3, and 1.22 for case 4. It is determined that the exergy efficiency gives precise information about the usability and sustainability of the system when these situations are evaluated. The exergetic improvement potential (EIP) was determined as 0.061 for case 1, 0.082 for case 2, 0.063 for case 3, and 0.059 for case 4, respectively. Although the highest exergy efficiency is obtained in case 3, it has a higher recovery potential than case 1 and case 4. In addition, cooling efficiencies for four different cases were obtained as 33.70%, 34.81%, 41.69%, and 36.95%, respectively. The temperature differences between the room and ambient temperatures were determined as 1.45 degrees C, 1.21 degrees C, 1.6 degrees C, and 1.48 degrees C for each case, respectively.