Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Coskun, Sevda" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Visibility Evaluation and Suitability Analysis of Fire Lookout Towers in Mediterranean Region, Southwest Anatolia/Turkiye
    (Mdpi, 2023) Cosgun, Ufuk; Coskun, Muecahit; Toprak, Ferhat; Yildiz, Damla; Coskun, Sevda; Tasoglu, Enes; Ozturk, Ahmet
    The effectiveness of fire towers in combating forest fires relies on their appropriate observation angles, enabling a swift and efficient response to fire incidents. The purpose of this study is to examine the effectiveness of 49 fire towers located within the Antalya Forestry Regional Directorate, situated in the Mediterranean basin-a region prone to frequent forest fires. The assessment encompasses the visibility of the entire study area, including forested regions, as well as the visibility of 2504 forest fires recorded by the towers between 2008 and 2021. Furthermore, the evaluation considers the objectives based on Forest Management Directorates and conducts a location suitability analysis for the six towers with the lowest visibility.We utilized the Viewshed Tool in the ArcGIS application and employed the Best-Worst approach. Two scenarios were devised, considering smoke height at 0 m or 100 m, to determine the visibility of fire lookout towers. In Scenario I, assuming a smoke height of 100 m, only three towers exhibited visibility above 70%. However, in Scenario II, assuming a smoke height of 0 m, no towers achieved visibility above 70%. Scenario I indicated that only two towers possessed a view of more than 70% of the forested region, while Scenario II suggested that no towers met this criterion. For the visibility of forest fires, Scenario I identified seven towers capable of observing more than 70%, whereas Scenario II indicated that no towers possessed such capability. In the tower suitability analysis, the visibility rates varied from 41.18% to 1016.67%. Based on the evaluation results, the current visibility capacities of the 49 fire towers proved insufficient for effective preventive measures.

| Karabük Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Kastamonu Yolu Demir Çelik Kampüsü, 78050 - Kılavuzlar, Karabük, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim