Yazar "Karaagac, Mehmet Onur" seçeneğine göre listele
Listeleniyor 1 - 5 / 5
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Assessment of a novel defrost method for PV/T system assisted sustainable refrigeration system(Pergamon-Elsevier Science Ltd, 2022) Karaagac, Mehmet Onur; Ergun, Alper; Gurel, Ali Etem; Ceylan, Ilhan; Yildiz, GokhanEnergy consumption has continuously increased depending on the rapidly growing human population, enlarging economies, advancing technologies, and improving living standards. A noteworthy share of the energy consumption has been arising from the buildings all across the world. Refrigeration, heating, and air conditioning systems have accounted for a significant portion of the energy consumption in the buildings. Therefore, it is possible to both reduce energy consumption, and mitigate the carbon footprints by efficiently designing, constructing, and operating these systems. In this framework, the present research has centered on the refrigeration systems, and aimed to develop a novel defrost method for photovoltaic thermal (PV/T) assisted sustainable refrigeration systems. In the conventional refrigeration systems, the frost process occurs when air condenses on the evaporator surface as a result of the evaporator surface temperature being below the freezing point of water or the dew point temperature of the air in the conditioned space. Differently in the present work, PV/T system is used to prevent the frost process in the refrigeration system, unlike the conventional systems. Accordingly, the efficiency loss caused by the temperature increment will be prevented by cooling the PV module, and it is aimed to be more efficient by reducing the daily power consumption as an alternative solution method to the frost that occurred on the evaporator in refrigeration systems. On this purpose, a novel evaporator design is developed, and used for defrosting in this study. Accordingly, this novel design includes a refrigerant line inside the evaporator and a hot water line from the PV/T in this design. In the results, it is noticed that the system designed for winter conditions could be used for defrosting. While an average of 605 W for heat energy was used for each defrost process, the average defrost duration was recorded to be approximately 4 min. While the average electrical efficiency of the PV module was found to be 13.6%, the average total efficiency was found to be 38%. Besides, Average PV module surface temperature was determined as 36.4 degrees C, average water storage tank temperature was determined as 26.4 degrees C. In addition, the coefficient of performance (COP) of the refrigeration system is calculated to be 4.18. COP increased by an average of 9% during defrosting. Furthermore, the environmental economic cost was calculated to be 14.6 $/h. In the conclusion, it is proven that the novel defrost method proposed in the present work can be used for refrigeration systems, and contribute to both the reduction of energy consumption and mitigation of carbon emissions arising from the buildings.Öğe A detailed analysis of a novel auto-controlled solar drying system combined with thermal energy storage concentrated solar air heater (CSAC) and concentrated photovoltaic/thermal (CPV/T)(Pergamon-Elsevier Science Ltd, 2023) Benlioglu, Muhammet Mustafa; Karaagac, Mehmet Onur; Ergun, Alper; Ceylan, Lhan; Ali, Ismail Hamad GumaIn recent years, the use of solar energy, one of the renewable energy sources, has been increasing in many areas due to its practical, environmental, and economic benefits. Besides, the drying industry is an applied area where solar energy can be implemented. Solar drying systems are used in the industry to reduce high drying costs and to obtain better quality products. In this study, a novel solar drying system was designed by combining concen-trated solar air collector (CSAC) and concentrated photovoltaic/thermal system (CPV/T). In addition, the automation system has been integrated for data acquisition from the system and humidity-temperature control of the drying chamber. The SAC's inlet air was preheated by a heat exchanger using thermal energy from the PV/T. The drying system has been designed to be more useful by using phase change material in the collector. Thus, the drying process can be performed on cloudy days and after sunset. In addition, the designed system can generate electricity from the PV module to meet the electricity requirement. The mint which grows in various regions worldwide was chosen as the product to be dried in this study. Mint was dried from the first moisture content of 3.3125 g water/g dry matter to the last moisture content of 0.0625 g water/g water/g dry matter. Besides, the average overall efficiency of the system, PV module electrical efficiency, and drying efficiency were found to be 61%, 10%, and 26%, respectively. Furthermore, the average system exergy efficiency, PV module exergy effi-ciency, and concentrated solar air heater exergy efficiency values were calculated as 20%, 16%, and 21.9%, respectively. In the experiment, the ambient average temperature was 22 degrees C, while the average drying chamber temperature was 30 degrees C. The mint drying quality efficiency was 67% on average at this drying chamber tem-perature. The energy, exergy efficiency, and sustainability index of the system were calculated as 61%, 38.8%, and 1.69, respectively. Moreover, the enviro-economic cost of the system was determined to be 0.39 (SIC)/h.Öğe Enhancing the performance of parabolic trough solar collectors: Cost-effective innovative designs for sustainable energy harvesting(Pergamon-Elsevier Science Ltd, 2024) Karaagac, Mehmet Onur; Akinci, Burak; Ergun, AlperThis study aims to improve the performance and stability of parabolic trough solar collectors (PTSC), especially those with heat storage capacity. Three different receiver tube designs have been meticulously developed to achieve this goal. As a result of the research, the Black surface (BS) -PTSC and PTSC- Paraffin wax (PW) systems achieved 26.5% and 56.8% more thermal energy flow, respectively, compared to the conventional PTSC. In addition, while the average thermal efficiencies of the PTSC, BS-PTSC, and PTSC-PW systems were found to be 11.2%, 14.1%, and 16.9%, respectively, the average exergy efficiencies of the PTSC, BS-PTSC, and PTSC-PW were 1.4%, 1.9%, and 2.3%. Painting the black copper pipe and filling the receiver tube with paraffin wax PCM increased thermal and exergy efficiency. Besides, comparing the temperature differences based on the PTSC system, it was found that BS-PTSC and PTSC-PW systems have 12.3% and 16.4% higher tank temperatures, respectively. The findings of this research have demonstrated the potential of parabolic trough solar collectors equipped with heat storage. It has also increased the sustainability index in terms of sustainability and reduced CO2 emissions into the atmosphere. Furthermore, it has been shown that these simple and inexpensive designs, without significant modifications to the system, can achieve high thermal performance without unnecessary expensive components.Öğe Experimental analysis of CPV/T solar dryer with nano-enhanced PCM and prediction of drying parameters using ANN and SVM algorithms(Pergamon-Elsevier Science Ltd, 2021) Karaagac, Mehmet Onur; Ergun, Alper; Agbulut, Umit; Gurel, Ali Etem; Ceylan, IlhanIn this paper, a concentrated photovoltaic-thermal solar dryer (CPV/TSD) using nano-enhanced PCM (Al2O3Paraffin wax) is experimentally studied. A comprehensive thermodynamic analysis of the system according to the first and second laws is discussed. Besides, the drying parameters (moisture content and moisture ratio) are predicted using the two machine learning algorithms (ANN and SVM) and compared the prediction success with four evaluation metrics (R2, rRMSE, MBE, and rMAE). The overall thermal energy efficiency and exergy efficiency of the CPV/TSD system are found to be 20% and 8%, respectively. Although solar radiation to the environment has decreased a lot, it has been found that the thermal energy transferred to the nano-enhanced PCM prevents the decrease in greenhouse temperature for the first 100 min. In the system, mushrooms are dried from the initial moisture content of 17.45 g water/g dry matter to the final moisture content of 0.0515 g water/g dry matter. Then the drying rate value for CPV/TSD system is calculated to be 0.436 g matter/g dry matter.min. On the other hand, even if both ANN and SVM algorithms have exhibited very satisfying results, ANN is coming to the fore in the prediction of the drying parameters considering all evaluation metrics together.Öğe Thermodynamic analyses of a novel hybrid photovoltaic-thermal (PV/T) module assisted vapor compression refrigeration system(Elsevier, 2023) Yildiz, Gokhan; Gurel, Ali Etem; Ceylan, Ilhan; Ergun, Alper; Karaagac, Mehmet Onur; Agbulut, UmitBuildings have a respectable share of global energy consumption and it is well-known that refrigeration, heating and air conditioning systems have crucially contributed to this share. Therefore, even a small improvement in these systems has a noteworthy potential in globally saving energy. Accordingly, the performance of Photovoltaic-Thermal module-assisted vapor compression refrigeration system (PV/T-VCRS) has been handled in the present research. PV/TVCRS has been integrated with PV module, refrigeration system, and their hybrid. Additionally, different from the conventional superheating methods, superheating has been performed with a PV/T module in this work. In order to discuss the system performance, and observe the differences between conventional and modified hybrid systems, energy and exergy analyzes have been applied. In the results, the average PV module surface temperature in PV module and PV/T-VCRS is recorded to be 56.16 degrees C and 40.93 degrees C, respectively. This case leads to a direct increment in PV module electrical efficiency. Electrical efficiency, average electrical efficiency in PV module, and PV/T-VCRS are calculated to be 13.49% and 14.69%, respectively. The average COP values are found to be 5.23 for VCRS, and 5.68 for PV/T-VCRS. Total exergy destruction in VCRS and PV/TVCRS has been calculated to be 175.85 W and 443 W. On the other hand, the exergy efficiency is found to be 50.79% in VCRS and 60.73% in PV/T-VCRS. In the conclusion, it is well-noticed that hybrid PV/T-VCRS presented promising results in terms of electrical efficiency, COP, energy, and exergy analyses as compared to those of the conventional system.