Multiplanar Semicircular New-Generation Implant System Developed for Proximal Femur Periprosthetic Fractures: A Biomechanical Study.

dc.authoridhttps://orcid.org/0000-0002-8762-5358
dc.authoridhttps://orcid.org/0009-0007-6268-9076
dc.authoridhttps://orcid.org/0009-0005-5340-6826
dc.authoridhttps://orcid.org/0000-0003-2363-0198
dc.authoridhttps://orcid.org/0000-0001-6885-1475
dc.authoridhttps://orcid.org/0000-0001-9354-3554
dc.authoridhttps://orcid.org/0000-0002-8927-2664
dc.authoridhttps://orcid.org/0000-0002-2039-7426
dc.contributor.authorSatılmış, Ahmet Burak
dc.contributor.authorÜlker, Ahmet
dc.contributor.authorUzunay, Zafer
dc.contributor.authorCengiz, Tolgahan
dc.contributor.authorTemiz, Abdurrahim
dc.contributor.authorYaşar, Mustafa
dc.contributor.authorMutlu, Tansel
dc.contributor.authorDaşar, Uygar
dc.date.accessioned2025-03-10T08:30:54Z
dc.date.available2025-03-10T08:30:54Z
dc.date.issued2025-01-14
dc.departmentFakülteler, Teknoloji Fakültesi, Endüstriyel Tasarım Mühendisliği Bölümü
dc.description.abstractThe study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study. A Vancouver Type B1 periprosthetic fracture was simulated by osteotomy 5 mm distal to the femoral stem. The models were divided into three groups: Group I (lateral locking plate fixation), Group II (lateral locking plate with cerclage wires), and Group III (new semicircular implant system). All fixation methods were subjected to axial loading, lateral bending, and torsional force testing using an MTS biomechanical testing device. Failure load and displacement were measured to assess stability. : The semicircular implant (Group III) demonstrated a significantly higher failure load (778.8 ± 74.089 N) compared to the lateral plate (Group I: 467 ± 68.165 N) and plate with cerclage wires (Group II: 652.4 ± 65.474 N; < 0.001). The new implant also exhibited superior stability under axial, lateral bending, and torsional forces. The failure load for Group III was more robust, with fractures occurring at the screw level rather than plate or screw detachment. : Compared to traditional fixation methods, the newly designed semicircular implant demonstrated superior biomechanical performance in stabilizing Vancouver Type B1 periprosthetic femoral fractures. It withstood higher physiological loads, offered better structural stability, and could be an alternative to existing fixation systems in clinical practice. Further studies, including cadaveric and in vivo trials, are recommended to confirm these results and assess the long-term clinical outcomes.
dc.identifier.citationSatılmış, A. B., Ülker, A., Uzunay, Z., Cengiz, T., Temiz, A., Yaşar, M., Mutlu, T., & Daşar, U. (2025). Multiplanar Semicircular New-Generation Implant System Developed for Proximal Femur Periprosthetic Fractures: A Biomechanical Study. Medicina, 61(1), 110. https://doi.org/10.3390/medicina61010110
dc.identifier.doi10.3390/medicina61010110
dc.identifier.issn1010-660X
dc.identifier.issn1648-9144
dc.identifier.issue1
dc.identifier.pmid39859092
dc.identifier.scopus2-s2.0-85215776214
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.3390/medicina61010110
dc.identifier.urihttps://hdl.handle.net/20.500.14619/15133
dc.identifier.volume61
dc.identifier.wosWOS:001405917700001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakPubMed
dc.indekslendigikaynakScopus
dc.indekslendigikaynakWeb of Science
dc.language.isoen
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.ispartofMedicina (Lithuania)
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectbiomechanics
dc.subjectfracture fixation
dc.subjecthip arthroplasty
dc.subjectimplant
dc.subjectnew generation
dc.subjectperiprosthetic fractures
dc.titleMultiplanar Semicircular New-Generation Implant System Developed for Proximal Femur Periprosthetic Fractures: A Biomechanical Study.
dc.typeArticle

Dosyalar

Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: