Energy and exergy analysis of surface water source heat pump system

dc.contributor.authorKocakulak, Serkan
dc.contributor.authorYilmaz, Sezayi
dc.contributor.authorErgun, Alper
dc.date.accessioned2024-09-29T16:06:49Z
dc.date.available2024-09-29T16:06:49Z
dc.date.issued2023
dc.departmentKarabük Üniversitesien_US
dc.description.abstractIn this study, energy and exergy analyzes were carried out to heat an experimental room with 28 square meter area by a surface water source heat pump (SWSHP) in the heating season, where placed in next to a river source (Arac stream) in Karabuk University. The system had a frequency inverter to change the compressor speed and the experiment was started at 35 Hz. in winter condition and completed when the indoor temperature reached 25.degrees C. While the COP value of the system was calculated as 2.58 on average, the highest exergy destruction was determined as 0.6 kW in the compressor in terms of the exergy analysis. The average exergy destructions were determined as 0.125 kW for the condenser, 0.152 kW for the expansion valve, 0.14 kW for the evaporator and fan coil system, and 0.06 kW for the water source heat exchanger. Exergy efficiencies were 60% for the compressor, 75% for the condenser, 85% for the expansion valve, 25% for the evaporator, 63% for the fan coil system and 8% for the water source heat exchanger. As a result of the study, it has been determined that the surface water source heat pump system works successfully in Karabuk province conditions.en_US
dc.identifier.doi10.2339/politeknik.1073209
dc.identifier.endpage1058en_US
dc.identifier.issn1302-0900
dc.identifier.issn2147-9429
dc.identifier.issue3en_US
dc.identifier.startpage1049en_US
dc.identifier.trdizinid1236150en_US
dc.identifier.urihttps://doi.org/10.2339/politeknik.1073209
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/1236150
dc.identifier.urihttps://hdl.handle.net/20.500.14619/7059
dc.identifier.volume26en_US
dc.identifier.wosWOS:000773337800001en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isotren_US
dc.publisherGazi Univen_US
dc.relation.ispartofJournal of Polytechnic-Politeknik Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectWater source heat pumpen_US
dc.subjectsurface wateren_US
dc.subjectCOPen_US
dc.subjectenergy and exergy analysisen_US
dc.titleEnergy and exergy analysis of surface water source heat pump systemen_US
dc.title.alternativeYüzey Suyu Kaynaklı Isı Pompası Sisteminin Enerji ve Ekserji Analizien_US
dc.typeArticleen_US

Dosyalar