Experimental Measurement of Tool-Chip Interface Temperature With Pyrometer in Turning

dc.contributor.authorDuran, Abdullah
dc.contributor.authorTurgut, Yakup
dc.contributor.authorGunay, Mustafa
dc.date.accessioned2024-09-29T16:06:48Z
dc.date.available2024-09-29T16:06:48Z
dc.date.issued2011
dc.departmentKarabük Üniversitesien_US
dc.description.abstractIn this study, tool-chip interface temperature occurred during machining of AISI 1040 steel with uncoated cemented carbide inserts were measured. Machining experiments were performed on a CNC lathe under dry conditions. In the experiments, five different cutting speeds (75-125-175-225-275 m/min), three different feed rate (0,1-0,2-0,3 mm/rev) and two different depth of cut (1-2 mm) were used. During cutting process, temperature values measured at the closest point to tool-chip interface were recorded to a personal computer using a pyrometer, fiber optic cables and other circuit elements. According to experimental results, it was determined that temperature generated on cutting zone increased with increases in depth of cut and feed rate. Additionally, tool-chip interface temperature increased with increasing cutting speed, but the tendency of increase in the temperature slightly decreased after cutting speed of 125 m/min.en_US
dc.identifier.doi10.2339/2011.14.4.297-301
dc.identifier.endpage301en_US
dc.identifier.issn1302-0900
dc.identifier.issn2147-9429
dc.identifier.issue4en_US
dc.identifier.startpage297en_US
dc.identifier.urihttps://doi.org/10.2339/2011.14.4.297-301
dc.identifier.urihttps://hdl.handle.net/20.500.14619/7047
dc.identifier.volume14en_US
dc.identifier.wosWOS:000447806500009en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.language.isotren_US
dc.publisherGazi Univen_US
dc.relation.ispartofJournal of Polytechnic-Politeknik Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCutting toolen_US
dc.subjectTemperature measurementen_US
dc.subjectAISI 1040en_US
dc.subjectPyrometeren_US
dc.titleExperimental Measurement of Tool-Chip Interface Temperature With Pyrometer in Turningen_US
dc.typeArticleen_US

Dosyalar