Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Frej, Alsediq S. S." seçeneğine göre listele

Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Evaluation of internal structure modifications effect of two-phase closed thermosyphon on performance: An experimental study
    (Pergamon-Elsevier Science Ltd, 2021) Ozbas, Engin; Selimli, Selcuk; Ozkaymak, Mehmet; Frej, Alsediq S. S.
    In this paper, an experimental study has been carried to enhance the effectiveness of a two-phase closed ther-mosyphon (TPCT) type heat pipe. For this purpose, three different designs have been developed by modifying the internal structure so as not to interfere with the physical operation of TPCT. Three heat pipes with different internal structures were manufactured with additional pipes placed longitudinally inside the evaporator and condenser sections of the normal (conventional) TPCT. Ionized pure water is used as a working fluid at the same rate in Normal, Type-1, Type-2, and Type-3 heat pipes. TPCTs are positioned at three different inclination angles, 26 degrees, 41 degrees, and 56 degrees, to see the performance effect not only among themselves but also on the changes made by the gravitational effect. For each tilt angle, four TPCTs were simultaneously powered by solar energy on three different days. As a result of the experiments carried out in July, it has been observed that the optimum incli-nation angle for solar water heated TPCT is 26 degrees. In addition, it was found that with the increase of the angle of tilt, the thermal resistance (R) of the heat pipes also increased and the heat transferability of the TPCT decreased. Comparing the new designs and normal TPCT, Type-2 acted better at tilt angles of both 26 degrees and 41oAs a result, the heat transfer and efficiency of normal TPCT have been improved by almost 14% with Type-2 at the tilt angle of 26 degrees.
  • Yükleniyor...
    Küçük Resim
    Öğe
    EXPERIMENTAL INVESTIGATION OF THE EFFECT OF INTERNAL STRUCTURE MODIFY ON PERFORMANCE IN TPCT TYPE HEAT PIPES DRIVING SOLAR
    (2020-01-27) Frej, Alsediq S. S.
    Heat pipes have be given great attention in solar energy applications, where they have great heat transfer potential. The purpose of this study is to experiment with the performance rate of a Tow-Phase Closed Thermosyphon (TPCT). The pipe is discharged from the air, while the water is used as a liquid to work at a rate of 1/3 of the size of the evaporator, and has been modified in the internal structure, by installing small pipes in different numbers inside the heat pipes in different cases, normal pipe, type I, type II and type III, then heat pipes are placed at different angles to receive solar radiation. It turns out that the value of solar radiation increases when the angle of inclination of the pipes is small, adjustment in the internal structure change the performance also, where the best performance was at the angle of inclination 26° of the modified heat pipe by adding two small tubes inside.

| Karabük Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Kastamonu Yolu Demir Çelik Kampüsü, 78050 - Kılavuzlar, Karabük, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim