dc.description.abstractA large part of energy cost on cooling applications is attributable to heat income through external walls. The best way to save energy is to use the optimum insulation thickness. In this study, the optimum insulation thicknesses, insulation-energy costs, and savings resulting from the use of these insulations is calculated in cities selected from four different climate zones in Turkey for four various insulation materials such as foamboard, extruded polystyrene (XPS), rock wool, and expanded polystyrene (EPS) in cold storage applications. Calculations show that rock wool insulation material yields the highest savings. Optimum insulation thicknesses vary between 0.074 and 0.159 m, energy savings vary between 30.59 and 80.61 $/m(2), and payback periods for investment cost vary between 3.15 and 3.73 years for the cooling. DOI: 10.1061/(ASCE)EY.1943-7897.0000085. (C) 2013 American Society of Civil Engineers.en_US
dc.identifier.doi10.1061/(ASCE)EY.1943-7897.0000085
dc.identifier.endpage59en_US
dc.identifier.issn0733-9402
dc.identifier.issue1en_US
dc.identifier.scopus2-s2.0-84874600935en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage54en_US
dc.identifier.urihttps://doi.org/10.1061/(ASCE)EY.1943-7897.0000085
dc.identifier.urihttps://hdl.handle.net/20.500.14619/5550
dc.identifier.volume139en_US
dc.identifier.wosWOS:000315466900010en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherAsce-Amer Soc Civil Engineersen_US
dc.relation.ispartofJournal of Energy Engineering-Asceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectOptimum insulation thicknessen_US
dc.subjectCooling costen_US
dc.subjectEnergy savingen_US
dc.titleEffect of Optimum Insulation Thickness on Refrigeration Costs for Different Climate Zonesen_US