Experimental investigation of collector efficiencies on separated and connected heat pipes

Küçük Resim Yok

Tarih

2008

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

The aim of study is to determine the effect of heat pipe systems to collector efficiency at solar collectors used in supplying hot water. For this purpose, two different collectors as the connected heat pipe and separated heat pipe have been produced. The experimental studies with the collectors have been conducted in Karabük city environment. The experiments have been completed in six days. The collector efficiencies have been calculated by measuring temperature of water tanks, ambient temperature and solar radiation in both collectors. As a result, while average efficiency of the connected heat pipe collector is 57.6%, average efficiency of the separated heat pipe collector is 48.5%.

Açıklama

Anahtar Kelimeler

Efficiency, Heat pipe, Solar collector

Kaynak

Journal of the Faculty of Engineering and Architecture of Gazi University

WoS Q Değeri

Scopus Q Değeri

Q2

Cilt

23

Sayı

2

Künye