The effect of thermal camera and pyrometer usage in industrial tempering furnaces on optimum combustion performance

dc.contributor.authorOzkaymak, Mehmet
dc.contributor.authorSelimli, Selcuk
dc.contributor.authorKaya, Durmus
dc.contributor.authorYilmaz, Esref
dc.contributor.authorTabak, Abdulsamed
dc.contributor.authorAksay, Mehmet Volkan
dc.date.accessioned2024-09-29T16:05:12Z
dc.date.available2024-09-29T16:05:12Z
dc.date.issued2015
dc.departmentKarabük Üniversitesien_US
dc.description.abstractThe decrease of energy sources, the increase of energy need and energy costs, competitive conditions in industry and environmental sensitivity require the effective usage of energy sources. In this study, optimum combustion study by using thermal camera and pyrometer in the correct heat furnace of an industry plant for the effective usage of energy in industry. For this reason, in tempering furnace of a milling roll workshop, in order to control the efficiency of tempering, detect the flame length and color and control the homogeneous tempering, 4 thermal cameras and 4 pyrometers have been assembled to the appropriate locations of the furnace. In the study, the tempering furnace has been observed and the results of observations have been evaluated. The contribution of the changes made to the production has been calculated by the information obtained from thermal camera and pyrometer and has been examined with the date of reimbursement. Possible spare part and production saving has been established as 364,460 $ annually and back-payment time as 3 months. Accident risk that is caused by the hot air and sometimes occurs during the controls has also been reduced so that the workers have been forced to work more safely according to WHS (workers' health and security).en_US
dc.description.sponsorshipScientific and Technological Research Council of Turkey\ [3110613]en_US
dc.description.sponsorshipThis study was supported by The Scientific and Technological Research Council of Turkey TEYDEB Program (Project number: 3110613).en_US
dc.identifier.doi10.1260/1708-5284.12.4.391
dc.identifier.endpage397en_US
dc.identifier.issn1708-5284
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-84960112402en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage391en_US
dc.identifier.urihttps://doi.org/10.1260/1708-5284.12.4.391
dc.identifier.urihttps://hdl.handle.net/20.500.14619/6565
dc.identifier.volume12en_US
dc.identifier.wosWOS:000218198600012en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherEmerald Group Publishing Ltden_US
dc.relation.ispartofWorld Journal of Engineeringen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectThermal cameraen_US
dc.subjectPyrometeren_US
dc.subjectCombustionen_US
dc.subjectIndustrial furnaceen_US
dc.titleThe effect of thermal camera and pyrometer usage in industrial tempering furnaces on optimum combustion performanceen_US