EFFICIENCY DETERMINATION OF SOLAR CHIMNEY POWER PLANT RETROFITTED WITH NOVEL FINNED COLLECTOR UNDER REAL-TIME SOLAR IRRADIANCE

dc.authoridEkiciler, Recep/0000-0003-1367-9465
dc.authoridARSLAN, Kamil/0000-0002-1216-6812
dc.contributor.authorHasan, Ibrahim Shikh
dc.contributor.authorPazarlioglu, Hayati Kadir
dc.contributor.authorArslan, Kamil
dc.contributor.authorEkiciler, Recep
dc.date.accessioned2024-09-29T16:06:27Z
dc.date.available2024-09-29T16:06:27Z
dc.date.issued2024
dc.departmentKarabük Üniversitesien_US
dc.description.abstractThis paper discusses the three-dimensional numerical study of a new finned collector integrated into the solar chimney power plant. Manzanares pilot's details, which are tower height 194.6 m, rooftop height 1.85 m, rooftop diameter 244 m, tower diameter 10.16 m, and pilot mean temperature 20 degrees C with air speed 15 m/s, are implemented in this work to check the suitability of the finned collector as a way of improvement. In order to assess the unique idea, a parametric study is done with different number of fins: 46, 33, and 25; different fin widths: 0.5, 0.25, and 0.1 m, and different fin heights: 1.2, 0.925, and 0.6 m. Therefore, optimal outputs could be obtained by the novel rooftop that is proposed in this study, where the efficient case is specified dimensionally by 46 fins, a fin width of 0.1 m, and a fin height of 1.2 m, which gives 1.674% as the station performance, 700.597 kW as the resulted power of the plant, 1790.3 as the Nusselt number, and 1.96E+14 as the Rayleigh number.en_US
dc.identifier.doi10.1615/HeatTransRes.2023049428
dc.identifier.issn1064-2285
dc.identifier.issn2162-6561
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-85188169895en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.urihttps://doi.org/10.1615/HeatTransRes.2023049428
dc.identifier.urihttps://hdl.handle.net/20.500.14619/6826
dc.identifier.volume55en_US
dc.identifier.wosWOS:001146591700001en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherBegell House Incen_US
dc.relation.ispartofHeat Transfer Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectcollector efficiencyen_US
dc.subjectnatural convectionen_US
dc.subjectsolar chimneyen_US
dc.subjectCFDen_US
dc.subjectfinned collectoren_US
dc.titleEFFICIENCY DETERMINATION OF SOLAR CHIMNEY POWER PLANT RETROFITTED WITH NOVEL FINNED COLLECTOR UNDER REAL-TIME SOLAR IRRADIANCEen_US
dc.typeArticleen_US

Dosyalar