NUMERICAL ANALYSIS OF THE STEAM TURBINE PERFORMANCE IN POWER STATION WITH A LOW POWER CYCLE

Küçük Resim Yok

Tarih

2023

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Taylor's University

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

In this paper, an analysis of the temperature and quantity balance of the thermal power plant for the Al-Dura (K-160-13.34-0.0068) station was first studied and used for reference. This work describes a possible way to build a simulation model of the most important parts of power plant Al-Dura (K-160-13.34-0.0068). The Cycle-Tempo and MATLAB/Simulink packages are used to model the energetic and exergetic analysis of the power plant. MATLAB/Simulink software was used to simulate the behaviour of a Steam turbine with high-pressure, intermediate-pressure, and low-pressure steam, with a load response in a stable circumstance over a range of 50% to 100%. The model is based on "Stodol's law" and simulates the pressure and enthalpy alongside the dissimilar turbine phases and the vapor and water extraction. The effect of the vapor and water extraction on the turbine is also elucidated. Areas of essential energy loss and exergy decimation will be resolved. The impact of changing the power plant load on the exergy analysis is determined. The response of suggested purposes to estimate these vapor properties is compared with standard data and showed high accuracy (the modelling error is less than 0.01%). © 2023 Taylor's University. All rights reserved.

Açıklama

Anahtar Kelimeler

Exergy, Extraction steam, MATLAB/Simulink software, Power plant, Reheated steam

Kaynak

Journal of Engineering Science and Technology

WoS Q Değeri

Scopus Q Değeri

Q3

Cilt

18

Sayı

Künye