Energy exergy efficiencies and environmental effects of mixed fuelled (solid plus gas) industrial facility steam boiler

Küçük Resim Yok

Tarih

2013

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Elsevier Sci Ltd

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

In this paper, an experimental study has been performed for mixed (solid + gas) fuelled boiler operating at 7000 kPa pressure and 778.15 K temperature with a nominal capacity of 25 kg s(-1) in order to find improvement in the boiler efficiency and to reduce its environmental emissions. In this scope, while the boiler was working under operating conditions, temperature, pressure, velocity, and combustion gas measurements were performed and the measured data were used to establish mass and energy balance. Main efficiency loses were identified as operation of the boiler with high excess air factor (39.78%), leakage air in the rotary air hater and surface thermal losses. Calculations, were performed with the use of measured data, estimated that the boiler and second law efficiency were calculated as 85.3 and 39.6% respectively. When the injected heat value on water is 67 433.65 kW in the boiler, by the reduction of excess air factor is 550 kW and by the prevention of leakage air is 1251.6 kW, including totally saving amount is 1801.7 kW. Financial value of this saving was calculated about 309 465$.

Açıklama

Anahtar Kelimeler

Steam boiler, Energy saving, Energy efficiency, Second law efficiency, Environmental effect

Kaynak

Journal of the Energy Institute

WoS Q Değeri

Q4

Scopus Q Değeri

Q1

Cilt

86

Sayı

4

Künye