Determination of optimum insulation thickness of external walls with two different methods in cooling applications

dc.contributor.authorKayfeci, Muhammet
dc.contributor.authorKecebas, Ali
dc.contributor.authorGedik, Engin
dc.date.accessioned2024-09-29T15:54:58Z
dc.date.available2024-09-29T15:54:58Z
dc.date.issued2013
dc.departmentKarabük Üniversitesien_US
dc.description.abstractThermal insulation is one of the most effective energy conservation for the cooling applications. For this reason, determination of the optimum thickness of insulation and its selection is the main subject of many engineering investigations. In this study, the optimum insulation thickness on the external walls in the cooling applications is analyzed based on two different methods used to determine annual energy consumption. One of the methods is the degree-hours method (Method 1) that is the simplest and most intuitive way of estimating the annual energy consumption of a building. The other is the method (Method 2) which using the annual equivalent full load cooling hours operation of system. In this paper, a Life Cycle Cost (LCC) analysis is used to evaluate accuracy of these methods, and the results are compared. The results show that the life cycle savings are overestimated by up to 44% in Method 2, while the optimum insulation thickness and payback period are respectively overestimated by up to 74% and 69% in Method 1. Crown Copyright (C) 2012 Published by Elsevier Ltd. All rights reserved.en_US
dc.identifier.doi10.1016/j.applthermaleng.2012.06.031
dc.identifier.endpage224en_US
dc.identifier.issn1359-4311
dc.identifier.issue1en_US
dc.identifier.scopus2-s2.0-84866523163en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage217en_US
dc.identifier.urihttps://doi.org/10.1016/j.applthermaleng.2012.06.031
dc.identifier.urihttps://hdl.handle.net/20.500.14619/4390
dc.identifier.volume50en_US
dc.identifier.wosWOS:000314191100025en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherPergamon-Elsevier Science Ltden_US
dc.relation.ispartofApplied Thermal Engineeringen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCooling applicationsen_US
dc.subjectThermal insulationen_US
dc.subjectExternal wallen_US
dc.subjectOptimum insulation thicknessen_US
dc.subjectLCC analysisen_US
dc.titleDetermination of optimum insulation thickness of external walls with two different methods in cooling applicationsen_US
dc.typeArticleen_US

Dosyalar