In vitro bioactivity and corrosion properties of laser beam welded medical grade AISI 316L stainless steel in simulated body fluid

dc.contributor.authorKöse, C.
dc.contributor.authorKaçar, R.
dc.date.accessioned2024-09-29T16:16:26Z
dc.date.available2024-09-29T16:16:26Z
dc.date.issued2016
dc.departmentKarabük Üniversitesien_US
dc.description.abstractAISI 316L stainless steel sheet was joined by CO2 laser beam welding method. In order to determine in vitro bioactivity and corrosion properties of the laser beam welded and non-welded samples were immersed in Simulated Body Fluid (SBF) for 1, 3, 7, 14, 21, 28 days. The bone-like apatite formation was investigated on the surface of the weld area and non-welded samples. Also, corrosion resistance of the laser beam welded and non-welded samples were determined via weight loss method. No corrosion mechanisms were observed in the heat affected zone (HAZ), weld metal of laser beam welded joints, and base material. © 2016 The Authors.en_US
dc.identifier.doi10.20964/110402762
dc.identifier.endpage2777en_US
dc.identifier.issn1452-3981
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-84963626882en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage2762en_US
dc.identifier.urihttps://doi.org/10.20964/110402762
dc.identifier.urihttps://hdl.handle.net/20.500.14619/9074
dc.identifier.volume11en_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherElectrochemical Science Groupen_US
dc.relation.ispartofInternational Journal of Electrochemical Scienceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBiomaterialsen_US
dc.subjectCorrosion testen_US
dc.subjectSurfacesen_US
dc.subjectWeldingen_US
dc.titleIn vitro bioactivity and corrosion properties of laser beam welded medical grade AISI 316L stainless steel in simulated body fluiden_US
dc.typeArticleen_US

Dosyalar