Effect of Boronizing and Shot Peening on the Fatigue Properties of an Iron Based FeCu-Graphite P/M Material

Küçük Resim Yok

Tarih

2014

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Carl Hanser Verlag

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Iron based materials manufactured by powder metallurgy (P/M) method are widely used in industry. These materials are very important in applications where no machining is required, they can also be used as journal bearing material due to their self-lubricated property, and can be used for applications in the medical industry. In this study, powder metal parts were manufactured from composites based on FeCu-graphite by P/M method. Fatigue test was carried out on manufactured samples, which were only treated by boronizing or boronizing and shot peeing. The fatigue properties of these parts were investigated by a rotating bending fatigue test rig.

Açıklama

Anahtar Kelimeler

Kaynak

Materials Testing

WoS Q Değeri

Q4

Scopus Q Değeri

Q2

Cilt

56

Sayı

2