Comparison of regular and irregular 32 pulse density modulation patterns for induction heating

dc.authoridOZBAY, Harun/0000-0003-1068-244X
dc.authoridkarafil, akif/0000-0002-7844-9014
dc.contributor.authorKarafil, Akif
dc.contributor.authorOzbay, Harun
dc.contributor.authorOncu, Selim
dc.date.accessioned2024-09-29T16:01:08Z
dc.date.available2024-09-29T16:01:08Z
dc.date.issued2021
dc.departmentKarabük Üniversitesien_US
dc.description.abstractIn this study, an induction heating (IH) application is carried out by transferring the maximum power extracted from photovoltaic (PV) panels to the stainless steel with the designed regular and irregular 32 pulse density modulation (PDM) controlled series resonant inverter. The main objective of this study is to analyse the changes in the system due to regular and irregular PDM patterns. Maximum power point tracker (MPPT) is used to control the output power at different solar irradiation values with varying PDM patterns. Regular and irregular PDM control methods are compared in terms of MPPT efficiency, cost, algorithm complexity, logic control structure and current/voltage stresses of the power switches. Zero current switching (ZCS) conditions are provided by using phase locked loop (PLL) technique at all power points of the PV system. The appropriate switching conditions are tracked continuously at resonant frequency, and therefore soft switching is realised. Perturb and observe (P&O) algorithm is used with the aim of tracking the maximum power in PV panels and high tracking efficiency is obtained with PDM-controlled P&O MPPT algorithm. ATMEL328P-AU microcontroller is used to control the inverter in the system.en_US
dc.identifier.doi10.1049/pel2.12012
dc.identifier.endpage89en_US
dc.identifier.issn1755-4535
dc.identifier.issn1755-4543
dc.identifier.issue1en_US
dc.identifier.scopus2-s2.0-85108005631en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage78en_US
dc.identifier.urihttps://doi.org/10.1049/pel2.12012
dc.identifier.urihttps://hdl.handle.net/20.500.14619/5524
dc.identifier.volume14en_US
dc.identifier.wosWOS:000606636400001en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherWileyen_US
dc.relation.ispartofIet Power Electronicsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSeries Resonant Inverteren_US
dc.subjectMppt Algorithmen_US
dc.subjectEfficiencyen_US
dc.subjectConverteren_US
dc.titleComparison of regular and irregular 32 pulse density modulation patterns for induction heatingen_US
dc.typeArticleen_US

Dosyalar