An energy efficiency analysis of an industrial reheating furnace and an implementation of efficiency enhancements methods

dc.authoridKilinc, Enes/0000-0002-9585-998X
dc.authoridTaylan, Osman/0000-0002-5806-3237
dc.contributor.authorKilinc, Enes
dc.contributor.authorKaya, Durmus
dc.contributor.authorKilic, Fatma Canka
dc.contributor.authorEyidogan, Muharrem
dc.contributor.authorOzkaymak, Mehmet
dc.contributor.authorTaylan, Osman
dc.contributor.authorPedrycz, Witold
dc.date.accessioned2024-09-29T16:05:12Z
dc.date.available2024-09-29T16:05:12Z
dc.date.issued2014
dc.departmentKarabük Üniversitesien_US
dc.description.abstractRapid consumption of energy resources, increasing energy needs, the competitive conditions in the industry and environmental concerns, all of those call for efficient use of energy resources. In this context, energy efficiency studies were carried out in a rolling mill of a reheating furnace of an integrated industrial enterprise. In studies, some important efficiency measurements were conducted, mass and energy balances were established by using the results of these measurements and the operating data of the plant along with energy saving opportunities, with the specified amounts and repayment periods were determined. Energy conservation studies that can be realized in the reheating furnace were considered including operation of the reheating furnace with the pertinent excess air coefficient, compensation of the air leakage losses in the recuperator and establishment of the economizer in the furnace. As a result of these investigations some saving opportunities were determined and a new recuperator, economizer and gas analyzer were installed in the reheating furnace leading in total of 2,913,924 kcal/h of energy savings. After the implementation of energy saving measures, reheating furnace efficiency was increased from 61.83% to 69.43%.en_US
dc.identifier.doi10.1260/0144-5987.32.6.989
dc.identifier.endpage1003en_US
dc.identifier.issn0144-5987
dc.identifier.issn2048-4054
dc.identifier.issue6en_US
dc.identifier.scopus2-s2.0-84921716742en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage989en_US
dc.identifier.urihttps://doi.org/10.1260/0144-5987.32.6.989
dc.identifier.urihttps://hdl.handle.net/20.500.14619/6562
dc.identifier.volume32en_US
dc.identifier.wosWOS:000348370100006en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherSage Publications Incen_US
dc.relation.ispartofEnergy Exploration & Exploitationen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectReheating furnaceen_US
dc.subjectEnergy analysisen_US
dc.subjectEnergy efficiencyen_US
dc.subjectEnergy conservationen_US
dc.subjectWaste heat recoveryen_US
dc.subjectEnergy auditen_US
dc.titleAn energy efficiency analysis of an industrial reheating furnace and an implementation of efficiency enhancements methodsen_US