Energy Saving and Emission Reduction Opportunities in Mixed-Fueled Industrial Boilers

Küçük Resim Yok

Tarih

2014

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Wiley-Blackwell

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

In this article, an energy efficiency study has been performed in an industrial establishment. The boiler of this industrial establishment is a mixed-fueled (solid+gas) type and operated with different fuels as coal, coke gas, and blast furnace gas, the pressure of 7000 kPa (70 bars) and temperature of 778.15 K (505 degrees C) and with a nominal capacity of 27.77 kg/s (100.000 kg/h) steam. In this context, the working temperature, pressure, velocity, and combustion gas measurements have been carried out at the boiler operation conditions. Using with all these measurements, the energy and mass balance equations have been set and the boiler efficiency has been calculated as the value of 85.91%. The main efficiency losses have been determined as: operating the boiler at the high air excessiveness coefficient, the air leakage in the rotary type air heaters and the heat losses of the surface. Total energy savings potential is 2,029,692 kcal/h. When anticipated enhancements can be carried out, the boiler efficiency will be 88.94%. In this case, 4861.7 tons of carbon dioxide emissions per year will be reduced. (c) 2014 American Institute of Chemical Engineers Environ Prog, 33: 1350-1356, 2014

Açıklama

Anahtar Kelimeler

steam boiler, energy savings, energy efficiency, emission reduction, exergy analysis

Kaynak

Environmental Progress & Sustainable Energy

WoS Q Değeri

Q2

Scopus Q Değeri

Q2

Cilt

33

Sayı

4

Künye