Energy saving and emission reduction opportunities in an industrial annealing furnaces

Küçük Resim Yok

Tarih

2014

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Gazi Universitesi Muhendislik-Mimarlik

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

In this study, "energy efficiency" study has been performed for a LNG (Liquefied Natural Gas) fuel annealing furnace. Within this frame, temperature, pressure, velocity, and gas analysis measurements have been made and energy and mass balances have been formed. From the measured data, the furnace total efficiency was calculated as 52.76%. The main efficiency losses: operating furnace at high air excessiveness coefficient, inadequacy of air preheater heater (recuperator) heat transfer surface area and surface thermal losses.

Açıklama

Anahtar Kelimeler

Annealing furnace, Emission reduction, Energy efficiency, Energy saving, Recuperator, Waste heat recovery