Comparison of PID and FUZZY controller in the cascade tank system in Matlab/Simulink

dc.contributor.authorBayir, R.
dc.contributor.authorErtunç, H.M.
dc.contributor.authorDemir, H.
dc.date.accessioned2024-09-29T16:22:12Z
dc.date.available2024-09-29T16:22:12Z
dc.date.issued2013
dc.departmentKarabük Üniversitesien_US
dc.description8th International Conference Intelligent Technologies in Logistics and Mechatronics Systems, ITELMS 2013 -- 23 May 2013 through 24 May 2013 -- Panevezys -- 122800en_US
dc.description.abstractIn this study present comparison of PID and FUZZY controller in the cascade tank system. In order to control cascade tank system, fuzzy and pid controller was simulated in Matlab/Simulink. The system has two tanks. The water level in the tanks and the stream provided by pump are the system parameters. The current which is applied to the motor is the only control variable in the system. In this system fuzzy controller are compared with pid controller. The signals of the system's output are observed in matlab.en_US
dc.identifier.endpage54en_US
dc.identifier.scopus2-s2.0-84983348048en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage50en_US
dc.identifier.urihttps://hdl.handle.net/20.500.14619/9870
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherKaunas University of Technologyen_US
dc.relation.ispartofIntelligent Technologies in Logistics and Mechatronics Systems, ITELMS 2013 - Proceedings of the 8th International Conferenceen_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCascade tank systemen_US
dc.subjectFuzzy logic controlleren_US
dc.subjectFuzzy logic typesen_US
dc.subjectPID controlleren_US
dc.titleComparison of PID and FUZZY controller in the cascade tank system in Matlab/Simulinken_US
dc.typeConference Objecten_US

Dosyalar