Yazar "Erden, Pinar Esra" seçeneğine göre listele
Listeleniyor 1 - 3 / 3
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Amperometric Biosensors for Tyramine Determination Based on Graphene Oxide and Polyvinylferrocene Modified Screen-printed Electrodes(Wiley-V C H Verlag Gmbh, 2019) Erden, Pinar Esra; Erdogan, Zehra Ozden; Ozturk, Funda; Kocoglu, Irem Okman; Kilic, EsmaA comparison of the analytical characteristics of two tyramine biosensors, based on graphene oxide (GRO) and polyvinylferrocene (PVF) modified screen-printed carbon electrodes (SPCE), is reported. Diamine oxidase (DAOx) or monoamine oxidase (MAOx) was immobilized onto the PVF/GRO modified SPCE to fabricate the biosensors. Surface characteristics and electrochemical behaviour of the modified SPCEs were investigated by atomic force microscopy (AFM), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX) and cyclic voltammetry (CV). Electrode surface composition and experimental variables such as pH and working potential were optimized in order to ensure a high performance. Under optimum experimental conditions, both DAOx/PVF/GRO/SPCE and MAOx/PVF/GRO/SPCE biosensors exhibited wide linear dynamic ranges for tyramine from 9.9x10(-7) to 1.2x10(-4) M and from 9.9x10(-7) to 1.1x10(-4) M, respectively. MAOx/PVF/GRO/SPCE biosensor showed higher sensitivity (11.98 mu A mM(-1)) for tyramine determination than the DAOx/PVF/GRO/SPCE biosensor (7.99 mu A mM(-1)). The substrate specifity of the biosensors to other biogenic amines namely histamine, putrescine, spermine, spermidine, tryptamine, beta-phenylethylamine and cadaverine was also investigated. The developed biosensors were successfully used for tyramine determination in cheese sample.Öğe Disposable biogenic amine biosensors for histamine determination in fish(Royal Soc Chemistry, 2020) Kocoglu, Irem Okman; Erden, Pinar Esra; Kilic, EsmaThis study presents the development of disposable biosensors employed in the determination of histamine in fish samples. Screen printed carbon electrodes (SPCEs) were first modified with a mixture of titanium dioxide nanoparticles (TiO2), carboxylated multiwalled carbon nanotubes (c-MWCNTs), hexaammineruthenium(iii) chloride (RU) and chitosan (CS). Diamine oxidase (DAO) or monoamine oxidase (MAO) enzymes were further immobilized onto the TiO2-c-MWCNT-RU-CS/SPCEsvia1-ethyl-3-(dimethylaminopropyl) carbodiimide hydrochloride (EDC) and hydroxysuccinimide (NHS) chemistry for the fabrication of the biosensors. The morphological and electrochemical properties of the proposed biosensors were studied using scanning electron microscopy (SEM), energy dispersive X-ray (EDX) spectroscopy, cyclic voltammetry (CV), chronoamperometry and electrochemical impedance spectroscopy (EIS). A performance comparison of two biosensors indicated that the one based on DAO had a linear concentration range from 9.9 x 10(-6)to 1.1 x 10(-3)M and the other based on MAO, from 5.6 x 10(-5)to 1.1 x 10(-3)M for histamine. The sensitivity of the DAO based biosensor was almost 1.5 times higher than that of the MAO based biosensor. The proposed biosensors were successfully employed to determine histamine in fish samples and the recoveries were between 100.0% and 104.6%.Öğe Disposable biosensor based on ionic liquid, carbon nanofiber and poly (glutamic acid) for tyramine determination(Academic Press Inc Elsevier Science, 2024) Kocoglu, Irem Okman; Erden, Pinar Esra; Kilic, EsmaIn this study, an electrochemical biosensor based on carbon nanofibers (CNF), ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate (IL), poly(glutamic acid) (PGA) and tyrosinase (Tyr) modified screen printed carbon electrode (SPE) was constructed for tyramine determination. Optimum experimental parameters such as CNF and IL amount, polymerization conditions of glutamic acid, enzyme loading, pH of test solution and operating potential were explored. The construction steps of the Tyr/PGA/CNF-IL/SPE were pursued by scanning electron microscopy and cyclic voltammetry. The Tyr/PGA/CNF-IL/SPE biosensor exhibited linear response to tyramine in the range of 2.0 x 10-7 - 4.8 x 10-5 M with a low detection limit of 9.1 x 10-8 M and sensitivity of 302.6 mu A mM-1. The other advantages of Tyr/PGA/CNF-IL/SPE include its high reproducibility, good stability and anti-interference ability. The presented biosensor was also applied for tyramine determination in malt drink and pickle juice samples and mean analytical recoveries of spiked tyramine were calculated as 100.6% and 100.4% respectively.