Experimental study of in-vitro bioanalysis and in-vivo living tissue biocompatibility of Mg-Zn alloys
Küçük Resim Yok
Tarih
2023
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Springer Heidelberg
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
In this study in-vitro bioanalysis and in-vivo living tissue biocompatibility were evaluated. Pure Mg and Mg + x Zn (x = 1 and 3 wt%) alloys have been used in the study. In vitro immersion and potentiodynamic corrosion were applied to these alloys in Hank's and artificial seawater solution. The materials were kept in living tissue (gluteus-superficial) for 7 weeks in-vivo (albino-rat). After 4 and 7 week, the control and experimental groups' urine parameters, blood mineral substance levels, and radiographic image controls were evaluated. It was observed that the bio-dissolution level decreased as the Zn-ratio increased. As a result, successful results were obtained in the biocompatible and biodegradable material class of Zn-doped Mg alloys used in the study. The dissolution amount of 1.03 mm/y (for Mg + 3Zn alloy) in Hank's solution was calculated. The % vitality was determined at the level of 117%.
Açıklama
Anahtar Kelimeler
Albino rat, Biocorrosion, Biomaterial, Mg alloys, Tissue implant
Kaynak
Journal of Materials Research
WoS Q Değeri
Q3
Scopus Q Değeri
Q2
Cilt
38
Sayı
8