dc.description.abstractIn this study, boriding process was carried out on ? 11 mm diameter DIN 20MnCr5 quality steel bars, used in chain elements such as links and rings, and fasteners such as bolts, at 950oC boronizing temperature, boriding times of 2.5 and 7.5 hours. In this study, the formation and growth of the boride layer and the metallographic structure, the coating thickness and corrosion properties of the boronized steels were investigated depending on the boriding conditions. In the box boriding process, Ekabor-II powder mixture, with its commercial name, was used as boriding powder. According to the optical microstructure results made as a result of box boriding, the coating thickness was 371.5 ?m in the ? 11 mm diameter boronized DIN 20MnCr5 steel bar for 7.5 hours boriding times while it was 195.6 ?m in that steel bar for 2.5 hours boriding times. Corrosion experiments were carried out in solutions prepared by adding 3.5% NaCl to distilled water. According to the results of the immersion test, the lowest corrosion rate in mdd was measured as 112 mg/(dm2 x day) in the ? 11 mm diameter, 7.5 hour boronized sample, and the highest corrosion rate in mdd was 1456.75 mg/(dm2 x day) in the untreated ? 11mm diameter sample. In the potentiodynamic polarization test, parallel results were obtained for immersion corrosion. Corrosion rate values (icor) were measured at the highest value of 209 x 10- 6 A/cm2 in the untreated ? 11 diameter sample, while the lowest icor value was 0.0039 x 10- 6 A/cm2 in the ? 11 mm diameter sample borided for 7.5 hours. © 2023 EDP Sciences. All rights reserved.en_US
dc.description.sponsorshipKarabük Üniversitesi, (KBÜBAP-22-YL-027)en_US
dc.identifier.doi10.1051/e3sconf/202340105035
dc.identifier.issn2555-0403
dc.identifier.scopus2-s2.0-85169679844en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.urihttps://doi.org/10.1051/e3sconf/202340105035
dc.identifier.urihttps://hdl.handle.net/20.500.14619/9539
dc.identifier.volume401en_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherEDP Sciencesen_US
dc.relation.ispartofE3S Web of Conferencesen_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleInvestigation of corrosion properties of box boring din 20MnCr5 steel barsen_US
dc.typeConference Objecten_US

Dosyalar