Molecular Epidemiological Analysis of Bacillus Pseudo-Outbreak due to Contaminated Culture Tubes Containing Stuart Medium

Küçük Resim Yok

Tarih

2022

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Clin Lab Publ

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Background: It is challenging to determine whether Bacillus species other than Bacillus anthracis cause infections. Pseudo and true outbreaks of Bacillus spp. have been noted. Here, we present a molecular analysis of a Bacillus spp. pseudo-outbreak caused by contaminated culture tubes containing Stuart medium. Methods: Between January and March 2015, a high percentage of Bacillus spp. was isolated from the wound samples of inpatients at the Karabuk University Hospital, and an outbreak was suspected. Environmental and staff nasal samples were cultured aerobically, and Bacillus spp. were isolated from some of them. However, the isolation of Bacillus spp. in throat cultures of outpatients suggested contamination caused by culture tubes containing Stuart medium. We examined two lots of culture tubes used in the hospital. Although the culture tubes' expiry date and storage conditions were suitable, Bacillus spp. grew in one of these lots. A total of 47 Bacillus spp. isolated during this period were identified, and the clonal relationship among the isolates was investigated by arbitrarily primed polymerase chain reaction. Results: Twenty-seven strains were identified as Bacillus megaterium and 20 as Bacillus firmus. Of the four strains isolated from the Stuart medium, two were identified as B. firmus and the other two were B. megaterium. Two B. firmus strains isolated from the Stuart medium and two B. firmus strains obtained from the coronary intensive care environmental samples were matched and clustered within the same genotype. We recalled all culture tubes containing Stuart medium. After another brand's culture tubes were distributed, no growth was observed. It was then understood that the pseudo-outbreak source was contaminated culture tubes containing Stuart medium. Conclusions: Microbiological controls of medical materials and equipment should be regularly checked to prevent outbreaks (true or pseudo).

Açıklama

International DNA Day and Genome Congress (IDDGC) -- APR 24-28, 2017 -- Ahi Evran Univ, Kirsehir, TURKEY

Anahtar Kelimeler

arbitrarily primed polymerase chain reaction, Bacillus firmus, Bacillus megaterium, molecular typing, pseudo-outbreak

Kaynak

Clinical Laboratory

WoS Q Değeri

Q4

Scopus Q Değeri

Q3

Cilt

68

Sayı

1

Künye